Technical Prospects is now DirectMed Imaging. Double the expertise, one comprehensive brand. Learn more.X

Everything You Need To Know About:

GE

Portable X-Ray 220

Brief Specifications About The GE Portable X-Ray 220

The Optima XR220amx is a self-contained battery operated mobile radiographic digital X-Ray imaging system designed for performing radiographic exams at the point of care when it is not safe or practical to move the patient to the radiographic room.

Optima XR220amx is suited for routine radiographic procedures within a hospital including radiology departments, intensive care units, cardiac care units, emergency departments, operating rooms, orthopedics, pediatrics, hospital rooms, and clinics.

 

  • FlashPad Lightweight detector designed for mobile use – weighs less than 4.5 kg (10 lbs.) including battery
  • “Stand-by” mode eliminates boot up cycles and allows exposure within 25 seconds
  • Designed for 24/7 availability. Use with battery or make and process exposures while the unit is charging
  • The detector can support up to 160 Kg (352 lbs.) of distributed load for bariatric applications
  • Detector battery charges automatically while the detector is in the bin
  • Automatic charging algorithms allow the system to be recharged even if batteries are not fully drained
  • 15kW (nominal) generator and available 30kW(nominal) option

 

GE Optima XR220amx Specifications

 

Wireless Digital Detector

  • Detector battery can take up to 50 exposures per hour and provide enough power for 3 hours of use on a single charge
  • Single panel (non-tiled) amorphous silicon detector with a Cesium Iodide scintillator
  • Image area: 40.4 cm x 40.4 cm (15.9 in x15.9 in)
  • Active matrix: 2024 x 2024 pixels
  • Pixel Pitch: 200 microns
  • Typical upper dynamic range: 7.8mR
  • Typical DQE: @ 0lp/mm: 68%)
  • Two handgrips

Detector Environmental Conditions

Temperature

  • Operating: 15°C to 35°C
  • Non-Operating: -0°C to 50°C (maximum change 20°C per hour)

Humidity

  • Operating: 10% to 80% RH, noncondensing(max. change 30% per hour)
  • Non-Operating: 10% to 95% RH, noncondensing (max. change 30% per hour)

Power

  • Capable of 100-240 V nominal, 50/60 Hz operation
  • System battery status display

X-Ray Source

  • Nominal Tube Voltage (Radiographic) 40 ~ 150 kV
  • Nominal Focal Spot size (IEC 60336):
    • Large Focus: 1.2 mm
    • Small Focus: 0.6 mm
  • Anode Rotation Speed (minimal): 3200 min-1
  • Permanent Filtration: 0.9 mm Al/75 kV IEC60522: 1999
  • Maximum X-ray Tube Current
    • Large Focus: 500 mA
    • Small Focus: 200 mA
  • Maximum Continuous Heat Dissipation: Without Air-circulator: 170 W (238 HU/s)
  • Maximum anode heat units: 140 kHU
  • Exposure time: 4.0 msec – 6.0 sec

[insta-gallery id=”2″]

Stay up to date with our resources!

We are constantly publishing new content! Learn MRI & CT industry secrets along the way, become a more informed buyer, learn how to troubleshoot even the most complex problems, and ultimately save time and money!

  • Hidden
  • This field is for validation purposes and should be left unchanged.

Did you know: We sell MRI & CT parts for GE, Siemens and Philips?

[carousel-horizontal-posts-content-slider-pro id=’108993′]

Customer Feedback

“When it comes to coil repairs, DirectMed is always our first choice. Ever since we started using DirectMed, our coil spend has decreased dramatically, all while receiving top notch customer service from a knowledgeable team.”

Jessica R., New Jersey

Radiology Director

“DirectMed Parts provides great service support, we have been their customer for almost two years now and this is greatly visible in our budget. We have cut our costs in half with the help of DirectMed Parts. Besides excellent service and support they also provide great equipment at very reasonable prices.”

Albert J., Tennessee

Service Technician